Table 7.
Comparative values of Fern and Ganop tests
in patients with sonographically proved
ovulation (n=21)
Results |
q |
+ |
++ |
+++ |
Total |
|
N |
% |
N |
% |
N |
% |
N |
% |
N |
% |
Fern test |
3 |
14.3 |
2 |
9.5 |
10 |
47.6 |
6 |
28.6 |
21 |
100 |
Ganop test |
2 |
9.5 |
3 |
14.3 |
8 |
30.1 |
8 |
30.1 |
21 |
100 |
X2=0.227;
DF=1; p>0.05 |
Comparative
values of FERN and GANOP tests in patients
with sonographically proved ovulation are
shown in table 7. There were 21 patients
with sonographically proved ovulation and,
out of these, FERN test was positive in
85.7% (18) cases while GANOP test was
positive in 90.5% (19) cases. Those
differences are not statistically
significant (Chi square=0.227; P>0.05).
The overall
review of FERN and GANOP tests results is
shown in table 8.
Table 8.
Comparative values of Fern and Ganop tests
(n=213)
Results |
q |
+ |
++ |
+++ |
Total |
|
N |
% |
N |
% |
N |
% |
N |
% |
N |
% |
Fern test |
68 |
31.9 |
45 |
21.1 |
55 |
25.8 |
45 |
21.2 |
213 |
100 |
Ganop test |
53 |
24.9 |
52 |
24.4 |
56 |
26.3 |
52 |
24.4 |
213 |
100 |
X2=2.879;
DF=3; p>0.05
(q:+) X2=2.597; DF=1;
p>0.05 |
Out of 213 examinations, the
results of FERN test were negative in 68
(31.9%) cases and positive in 145 (68.1%)
cases. As for GANOP test, the results were
negative in 53 (24.9%) and positive in 160
(75.1%) cases.
As for different
modalities of positive FERN test, the
results were marked by (+) in 21.1% cases,
by (++) in 25.8% and by (+++) in 21.2%
cases. Positive GANOP test results were
marked by (+) in 24.4% cases, by (++) in
26.3% and by (+++) in 24.4% cases.
There was no
statistically significant difference between
both tests either for modalities of
positive results (Chi square =2.879; P>0.05)
or for the ratio of positive and negative
results (Chi square=2.597; P>0.05).
-
|